停機期間純化水設備該如何維護 |
||
純化水設備如果遇到假期,需要較長時間的停運,那么,我們需要對純化水設備做好維護工作,避免應長時間的停運影響純化水設備的性能。對于純化水設備的維護,如下解析: Purified water equipment, if you encounter a holiday, the need for a longer period of time, then, we need to do a good job of maintenance of purified water equipment, to avoid a long period of time the impact of water purification equipment. For the maintenance of purified water equipment, the following analysis: 1.三天內的停運,應每天用保安過濾器進行30分鐘的沖洗,并確保反滲透組件內的過濾水充滿; 1 within three days of the outage, the security filter should be used every day for 30 minutes to wash, and ensure that the reverse osmosis module is filled with filtered water; 2.超過三天的停運,則需要將1%的甲醛溶液灌滿反滲透組件,然后關閉所有的閥門,定期進行檢查,如果是在冬季,為了防凍必要時可加入10%~20%的甘油,如果在夏季,則要控制環境的溫度以防發霉變質; More than 2 outage three days, you will need 1% Formaldehyde Solution full reverse osmosis module, then close all valves, check regularly, if it is in winter, in order to freeze may be necessary to join 10%~20% glycerol, if in the summer, to control the temperature of the environment to prevent mildew deterioration; 3.建議可將反滲透淡水作為保存用水; 3 recommendations can be used as the preservation of fresh water; 4.如果反滲透裝置中采用的是復合膜,并且停運到一周以上,那么,我們應該講1%的亞硫酸氫鈉溶液進行浸泡來抑制細菌的滋生。 4 if the reverse osmosis device is used in the composite membrane, and outage for more than a week, then, we should talk about 1% of the Sodium Bisulfite solution to inhibit the proliferation of bacteria. 更多純化水設備信息可訪問北京中程瑞源科技有限公司網站:http://www.sdfygt.com/ More information can visit the Beijing water purification equipment in the process of Ruiyuan science and technology limited company website: http://www.sdfygt.com/ |