實驗室純水機不出水的原因有哪些 |
||
隨著生產科技的發展,實驗室純水機的應用越來越廣泛,但是大家在使用超純水機的過程中常常會出現機器不出水的故障,那么,引起實驗室超純水機不出水的原因有哪些呢? With the development of production technology, laboratory pure water machine is used more and more widely, but everyone in the use of ultra pure water machine in the process often fails, no water machine that causes laboratory ultra pure water machine water is not what?
System does not make water 1、可能是自來水沒開或水壓不夠,系統會發出報警聲,打開自來水或短接低壓保護開關。短接可能會造成增壓泵空轉而損壞泵。 1, may be the tap water is not open or water pressure is not enough, the system will issue a warning sound, open the tap water or short connect low voltage protection switch. Short circuit may cause damage to the pump and booster pump idling. 2、可能是預處理濾芯堵塞,水通量減小或沒水通過,更換預處理濾芯。 2, may be a pre filter filter clogging, water flux decreases or no water through, replace the pretreatment filter. 3、低壓保護開關損壞,不能正常閉合,更換低壓保護開關。 3, low voltage protection switch is damaged, can not be normally closed, the replacement of low voltage protection switch. 4、高壓保護開關損壞,不能正常閉合,此時滿水指示燈會亮,更換高壓保護開關。 4, high voltage protection switch is damaged, not close properly, then full of water LED lights to replace the high voltage protection switch. 系統一直造水:高壓保護開關損壞,不能正常斷開,制水指示燈一直亮,更換高壓保護開關。 System has been made water: high voltage protection switch is damaged, can not normally open, water indicator light has been lit, the replacement of high voltage protection switch. 系統制水、滿水轉換太頻繁:可能是純水桶球閥未打開,不能儲水,打開純水桶球閥。 System to make water, full water conversion is too frequent: may be pure water bucket ball valve is not open, can not store water, open a pure bucket ball valve.
系統造水量偏小 System water consumption is small1、可能是反滲透膜堵塞,更換反滲透膜。 1, may be the reverse osmosis membrane plug, replace the reverse osmosis membrane. 2、可能是供水不足,改善供水或更換預處理濾芯。 2, may be inadequate water supply, improve water supply or replace the pretreatment filter. 3、可能是增壓泵損壞,更換增壓泵。 3, may be damaged to the booster pump, replace the booster pump.
三級產水水質差:可能反滲透膜被損壞,更換反滲透膜。 Three water quality is poor: may reverse osmosis membrane is damaged, replace the reverse osmosis membrane.一(三)級取水量。 實驗室超純水機,超純水機 One (three) level of water quantity is small: the laboratory ultra pure water machine, ultra pure water machine 可能是(超)純化柱失效,更換(超)純化柱。 May be (ultra) purification column failure, replacement (super) purification column. 可能循環管路上的單向閥損壞,造成水沒有通過(超)純化柱直接通過循環管路反向出水,更換循環管路上的單向閥。 May be caused by a one-way valve on the pipeline valve damage, resulting in water is not through the (super) purification column directly through the circulating pipeline reverse water, replace the one-way valve on the loop line. 可能純水箱內水太少,等系統滿水后再取水。 May be too little water and pure water tank, filled with water after the water intake system. 可能是純水箱氣囊內壓力過低或無壓力,重新給純水箱氣囊充氣。 May be pure water tank air bag pressure is too low or no pressure, to pure water tank air bag inflation. 一級出水水質差 First grade effluent water quality difference 可能沉積水太久,將其排掉。 May deposit the water too long, it will be discharged. 可能循環泵損壞,不能進行循環處理,更換循環泵。 May be damaged by the pump, can not be carried out recycling, replace the circulating pump. 系統功能不正常:可能是系統電路損壞,更換電路板。 實驗室超純水機,超純水機 System function is not normal: the system may be damaged, replace the circuit board. Laboratory ultra pure water machine, ultra pure water machine 一(三)級不出水:可能是一(三)級取水電磁損壞,更換一(三)級取水電磁閥。 One (three) level does not water: may be a (three) level of water damage, the replacement of a (three) level of water intake solenoid valve. 系統排放不出水:可能是系統排放電磁損壞,更換系統排放電磁閥。 System discharge is not water: may be the system discharge electromagnetic damage, the replacement of the system discharge solenoid valve. 系統沖洗不出水:可能是系統沖洗電磁損壞,更換系統沖洗電磁閥。 The system does not wash water: the system may be damaged, the replacement of the electromagnetic valve replacement system. 以上就是有關實驗室純水機不出水的故障解決辦法,如果還不能解決您的問題,可以咨詢產品的售后工程師,幫您盡快解決您的疑問。 The above is about the laboratory pure water machine does not water the fault solution, if you can not solve your problem, you can consult the product engineer, to help you solve your question as soon as possible. |